Filter › Mercury Removal Tower

Sulphuric Acid

Filter › Mercury Removal Tower

SULPHURIC ACID Mercury Removal Tower

PROCESS INFORMATION

Mercury Removal Towers can be installed as part of the Gas Cleaning section upstream of a Sulphuric Acid contact plant, where solids and other impurities are removed.
The exit of the Mercury Removal Tower should be fitted with a suitable droplet separator to prevent carry-over from the tower. Boliden Norzink example shown below:

Mercury Removal Tower diagram

PROBLEMS TO SOLVE

Contamination of downstream equipment and process

DESIGN SOLUTION

Polypropylene chevron vane system and / or a knitted Polypropylene demister

Usually a Chevron vane and a knitted wire demister are used in series to prevent the droplet carry-over of contaminated materials from a Mercury Removal tower.

Conventional design PP demisters can be fragile in this duty since they are subject to frequent maintenance handling, being taken in and out for cleaning.
The SWISS design demister is much more robust in terms of support grids, with integral side sheets for easier installation, and less risk of damage. See the difference in construction shown in the photograph below – SWISS style on the left, standard style on the right.

 

Chevron vane and a knitted wire demister are used in series to prevent the droplet carry-over of contaminated materials from a Mercury Removal tower

 

 

 

 

 

 

We are now offering also BlueFil® meshpads for the 2nd stage demister service, with the benefits of a strong mesh pad design, easy to install, remove, wash and re-use.  We can also design a BlueFil® pad to do the combined chevron vane & demister duty in a single stage, with no loss of performance.

Bluefil Mesh Pads Performance chartMercury Removal Tower Demister