Air is compressed on site for instruments, power tools etc.
These compressors can entrain water or oil into the air.
Up to 70,000 mg/m3 of oil and/or water can be present.
PROBLEMS TO SOLVE
Contamination of air quality.
Water or oil in compressed air damaging instruments / power tools etc., and freezing in cold weather.
DESIGN SOLUTIONS
Basic Design A – ‘Becoil’ Demister in 304 Stainless Steel
Basic Design B – ‘Becone’ Coalescer / ‘Becoil’ Demister in 304 Stainless Steel with added Glass fibre.
Improved Design – High Efficiency ‘Becofil’ Candle Filters, hanging type HT, with TGW15 or B14W Glass Fibre elements and 304L Stainless Steel or Carbon Steel structure.